Machine Enclosures

Machine Enclosure

Configuration includes drop ceiling with non-shedding tile, 20 psf roof, standard electrical kit and steel door. Windows are optional. Layout is customized to your requirement.

Specifications

ItemMachine Enclosure
ColorWhite (8 mil thick) (optional Gray or Tan)
Depth20 ft. 4-1/2" (quantity 2)
Width20 ft. 4-1/2" (quantity 2)
Height10 ft. 1-3/4" (for preferred ceiling height)
Outlets7
WindowsOptional
HardwareAll connecting hardware to make a complete clean room
ConditionNew
InsulationR-8
LED Lights7
Fire RatingClass A+ Non-Combustible 40 minute thermal barrier
Frame ColorWhite (optional Gray or Tan)
Door w/glassHeavy duty steel 40" x 84" , with ADA lever lockset
Breaker Panel1
Panel MaterialVinyl Covered 5/8" type "X" gypsum on two sides, laminated to a thermal insulated EPS core
Roof and Ceiling22 Gauge corrugated galvanized or prime coated steel roof deck and 2 x4 drop ceiling non-shedding tile with white grid. Steel support for 20 psf maintenance load provided.
Fire Test StandardsASTM E84
Wall Thickness and Width3 inches thick, nominal 4 ft wide (or 2 ft as required)
Sound Transmission CoefficientSTC35

What's included

  • Sound Deadening Walls STC 35 (better noise reduction than other brands - STC 35 glass upgrade available).
  • Fire rated to Class A+ 40 minute thermal barrier (nearly 3x better thermal resistance than other brands).
  • EXCLUSIVE: DiamondCoat Durable 8 Mil White vinyl wall finish (33-100% thicker than other brands).
  • Easily cleanable smooth wall finishes so particulate does not get trapped in a coarse surface
  • 10 foot high walls for a higher preferred ceiling height and deeper plenum area.
  • Steel Door and Jamb (Larger) 40"x84", The industry's best door features: Heavy duty 20 ga. door, 16 ga. jamb, Galvanized steel, Powder coated finish, larger for better access 40x84, Gasketed jamb for sound conditioning, ADA Lever lockset, and 3 heavy duty hinges.
  • Stronger 3" thick hardwall panels, not flimsy thin walls and not bulky thick walls. 3" thick walls offer the optimum thickness for strength and performance, without adding unnecessary core thickness costs.
  • Non-progressive interchangeable component design. Easily change your configuration to move door, window or solid wall panels, and electrical without disturbing adjacent wall panels. All components are consistently sized to provide maximum flexibility; that's something most of our rivals can't say.
  • Roof Load Design includes beams 8'o.c., for a 20 PSF maintenance load to support ductwork and filtration.
  • Build for Change. You don’t just purchase a clean room from us, you purchase a system. A system you can add to for a larger cleanroom, reconfigure, convert to multi levels, take down and move; the possibilities are endless.

Options & add-ons

Selected with a project specialist after you order. Online add-on selection is part of the production build.

Steel Wall Surface Add-On SG2$6,814.00
CleanWall Option S2$5,022.00
Window 4' x 4'-High, Half Light$120.00 each
Window 4' x 4'-High, Half Light - Sound Deadening Glass STC 35$390.00 each
Steel Door 40" x 84"-High, with window, *extra$1,110.00 each
Data/Communication Basic Prep$60.00 each
Modular Wiring Option$1,681.00
Framed Wall Cutout$195.00 each
Steel Double Door 80" x 84"-High, With Windows$2,590.00 each
You provide
  • An Electrician (for wiring, ceiling conduit, power and breaker panel hookup)
  • Assembly, if not purchased.
  • Delivery, if not purchased. Shipments can be sent by LTL common carrier; which is usually required for longer distances.
  • HVAC, Mechanical System, and Filtration. (to be contracted separately and locally by customer with a mechanical contractor)
  • All optional items not purchased.
Not included
  • Customizing or resizing of any components
  • Taxes (we only charge sales tax in TN)
  • Permits or fees
  • Engineering services, sealed drawings, or calculations.
  • Seismic zone consideration
  • Structural steel finish, other than prime first coat
  • Floor or floor finishes. Our walls anchor to your existing concrete slab.
  • Windows, HVAC, Assembly, and Delivery are all optional and not included items.
  • HVAC, Mechanical System, and Filtration are not included.
  • Items not included can be added as required.